Operating manual binder co2 incubator




















The HIC will adhere to the specific guidelines recommended by Binder for the use and maintenance of the CO2 incubator. The specific policy will be outline below for use and care of the incubator. This will also include the proper documentation indicating that the maintenance recommended has been completed and also Operating instructions.

Hot-Air Disinfectable Gassed Incubator. BBD Read this operating instructions and keep it near the equipment for reference purposes! Valid: Service Manual. CO2 Incubator. FILE No. Note ; Model name. C: Copper alloy anti-bacteria stainless steel. A: Air jacket. CO: CO2 Incubator. M: Medical equipment Two chrome-plated racks included. BD series incubators from BINDER with gravity convection are specially designed for long-term and stable continuous operation, ideal for gentle incubation of organisms, as well as conditioning of heat-sensitive media.

Incubators with gravity convection. BD series. Available sizes liters. The third edition of the WHO Laboratory biosafety manual is a helpful reference and guide to nations that Boekel Incubator. Catalog Number. Positioning the CO2 incubator. Where you place the incubator can alter its performance.

Ventilation, air flow, room temperature, and direct sunlight can all affect the temperature and humidity functions. When installing a CO2 incubator, be sure to. Drying ovens. ED series.

FD series. FED series. FP series. Vacuum drying ovens. VD series. Decreasing supply pressure will result in longer recovery times. Conversion table for gas inlet pressures, bar — Connect the pre-assembled hose nozzle of the gas hose to the quick acting closure socket 11 DN 6 on the chamber rear, as described in chap. Chamber rear Figure Connecting the hose lead to the gas cylinder Now fit the hose nozzle c in the quick acting closure socket.

To remove the connection, pull the hose nozzle off the quick acting closure socket. A reusable measuring equipment to assess the water quality is included chap.

Page Water Supply Installation 4. The lifetime depends on water quality and the amount of treated water used. The measuring equipment to assess the water quality is reusable. Do not press too hard while closing them to avoid pushing the doors through the gasket into the inner chamber. Operating mode Temperature values Page Operating Functions In Normal Display Operating functions in normal display Current operating mode Text list for information icons Date, time, authorization level of the logged-in user, memory Quick setpoint entry Continue to next screen Back to Normal display Information Program start Setpoint entry Event list Display of active alarms Access to main menu Figure Operating functions of the MB2 controller in normal display sample values, chamber with O Page Display Views: Normal Display, Program Display, Chart-Recorder Display Display views: Normal display, program display, chart-recorder display Press the Change view icon to toggle between normal display, program display and chart- recorder display.

Press the Normal display icon to return from program display and chart recorder display back to Normal display. Data recording History display continues. The chamber approximates ambient values. Page Controller Menu Structure Controller menu structure Use the navigation icons in the screen footer in Normal display to access the desired controller functions. This is selected either during login or can be available without password protection.

Page Principle Of Controller Entries Principle of controller entries In the selection and entry menus there are icons displayed in the footers which you can use to take over the entry or cancel it. Entry menu example Selection menu example After completing the settings there are the following possibilities: Press the Confirm icon to take over the entries and exit the menu or continue the menu sequence. Page Performance When Opening The Door To reduce odors quickly we recommend heating up the chamber to its nominal temperature for one day and in a well-ventilated location.

Afterwards occurs a request of the time zone and the temperature unit. The controller will function in the operating mode, which was active before the last shut-down. It controls temperature, CO chamber with O control and humidity chamber with active humidification in fixed Page Entering The Altitude Of The Installation Site Entering the altitude of the installation site After first turning on the chamber, it is required to enter the altitude above sea level of the installation site into the controller.

This entry serves to correct the calculation of CO concentration in vol. Depending on the required range of O concentration, the type of gas which is required may vary. To this end, two equipment variants are available: 6. All settings made in Fixed value operating mode remain valid until the next manual change. Normal display. Enter the to change. Vent out any CO gas that may escape via good room ventilation or a suitable connection to an exhaust system. Page Timer Program: Stopwatch Function Timer program: stopwatch function During an entered duration the controller constantly equilibrates to the setpoints entered in Fixed value operation mode temperature, CO chamber with O control , humidity chamber with active humidification , configuration of the operation lines.

During the program runtime, any setpoint changes do not become effective; The program is paused. The program runtime stops running down, the time display flashes. There are the following options: Press the Program start icon to continue the program Press the Cancelling icon to cancel the program 8. Page Time Programs Time programs The MB2 program controller permits programming time programs with real-time reference.

It offers 25 program memory positions with up to program sections each. Modifications of these setpoints are effective. When the configured moment for program start is reached, the program delay time ends and the program starts running. Select an empty program place. Press the Confirm icon. This menu point is visible only after a program has been copied.

Section view example: section 1. Then select whether to insert the new section before or after the current section. The new section opens. Page Deleting A Program Section Press the Edit icon to open the section editor if you want the current section to be replaced or the copied section to be inserted before or after it Program view. Select the section to be replaced or before or Press the Edit icon to open the section editor after which the copied section shall be inserted example: section 2 and press the The section view gives access to all parameters of a program section.

You can enter or modify the values. Program name and section number Section duration Type of setpoint transition: ramp or step Operation lines Page Setpoint Entry 9. Confirm entry with Confirm icon. The controller returns to the section view. Setting range: to Page Saving The Time Program 9. Program view. After the all desired values of the program Press the Confirm icon to take over the section have been configured, press the programming.

Confirm icon to take over the programming. The controller changes to the Normal display. The controller changes to the program view. Page Week Programs Week programs The MB2 program controller permits programming week programs with real-time reference.

It offers 5 week program places in total with up to shift points for each week program. Page Program Editor: Program Management If a new program has been created, there is Select an existing program just one program section.

Therefore the section is first marked in red and The program view opens. A new section is always added at the very bottom example: section 3. Page Section Editor: Section Management Confirm icon. Therefore the section is first marked in red and cannot be saved. Section view. If this condition persists, in some cases an alarm will be triggered after a fix or configurable interval. As long as the condition persists, the information icon therefore continues to be displayed also in state of alarm.

Page Alarm Messages Page State Of Alarm Visual indications in Normal display: alarm message, screen header flashing in red color 2. Audible alert, if the buzzer is enabled chap. In some cases: Switching the zero-voltage relay alarm output chap. Line Series FD Classic.

Line Series FP Classic. Line Series M Classic. Time program editor for chamber controller MB2 Version 1. Thermoelectric cooling technology Will Peltier modules supersede the compressor?

BCW weekly program editor Version 1. Trends in consumer behavior How has the food industry changed in industrialized countries? Weekly program editor for chamber controller MB2 Version 1. BCW time program editor Version 1. Connection Tester v1.